Enter the height from floor to floor and the tread you want. See how many steps you need, how much space the stair takes and whether it meets SANS 10400-M.

Stair calculatorFree tool · FloorPlan.co.za

01Heights millimetres

02The steps

Risers
–
Riser height
–
Treads
–
Total going (run)
–
Pitch
–
Stairwell opening, about
–
Floor space, about
–

    A stair takes more space than most people expect, and it is one of the first things a building inspector checks. This calculator works out the steps for a straight stair from the height between the floors: how many risers, how high each one is, the number of treads, the length of the stair and the opening it needs in the upper floor, and it checks the riser and going against the limits for houses in SANS 10400-M.

    The limits for a stair in a house

    SANS 10400-M, the part of the national building standard that covers stairways, sets limits for the steps. Summaries of the standard give, for a stair inside a dwelling:

    • a riser of not more than 200 mm;
    • a going (the tread depth, measured nosing to nosing) of at least 250 mm;
    • headroom of at least 2.1 m, measured up from the pitch line;
    • a landing where the rise between landings would be more than 3 m.

    Every riser in a flight must be the same height, and every going the same depth, so the calculator divides the floor-to-floor height into equal risers. Handrails, balustrades, the width and stairs in other kinds of buildings have their own requirements: your draughtsperson works to the current edition of the standard, which is the one that counts.

    Planning the stair in a double storey

    A straight stair for an ordinary double storey is around 3.5 m long and needs an opening in the upper floor of most of that length, so it shapes the plan of both floors. Quarter-turn and half-turn (dog-leg) stairs fold the same steps into a squarer space. The floor-to-floor height is the ceiling height plus the thickness of the upper floor and its finishes, so a higher ceiling adds a step or two. When you add a storey to an existing house, the stair is often the hardest thing to fit: see Extension Plans.

    Reading the results

    The pitch is the angle of the stair; shallower stairs are easier to climb and take more floor. The stairwell opening is roughly how long the hole in the upper floor must be for 2.1 m headroom, based on the floor thickness you enter. The floor space is the length of the stair times its width plus a square landing at the top. A draughtsperson will refine all of this on the building plans.

    Frequently asked questions

    What is the maximum riser height in South Africa?
    Summaries of SANS 10400-M give 200 mm as the maximum riser for a stair in a house, with a going of at least 250 mm. Check the current edition of the standard with your draughtsperson.
    How many steps for 3 metres?
    At 200 mm risers at most, a 3,000 mm floor-to-floor height needs 15 risers of 200 mm, or 16 of 187.5 mm for an easier stair. There is always one tread fewer than risers.
    How long is a staircase for a double storey?
    With a 2,950 mm floor-to-floor height, 15 risers and 250 mm treads, a straight stair has 14 treads and runs 3.5 m, plus a landing at the top.
    What headroom does a stair need?
    At least 2.1 m, measured vertically from the pitch line (the line along the nosings) to anything above it, such as the edge of the upper floor.

    Sources

    A guide for planning only. Your draughtsperson, architect or engineer and your municipality have the final word.

    Free quote request

    Request plan quotes

    Write the brief the way a draughtsperson would ask for it: the project, the rooms or the size, and where you are. Draughtspersons and architects who work in your area quote you directly.

    Client briefDwg HD-04 · scale 1:100

    01The project

    02The plan (optional, it sizes the job)

    BLOCK PLAN · NOT TO SCALE

    Floor area
    -
    Rooms
    -
    Storeys
    -
    Drawing fee
    -

    Choose the rooms to draw the plan. It is a sketch for the draughtsperson, not a design.

    Extras

    03Stand and timing

    04Drawing list (optional)

    1. L01
    2. L02
    Up to 12 lines: drawings, views or visits.
    Needs and options

    05Your details

    Free and no obligation. By sending you agree that we may share your request with suitable draughtspersons, architectural technologists or architects. See our privacy policy.

    Get free plan quotes