Get quotes

Free tool

Room size and ventilation checker

Enter a room's size, ceiling height and the windows that open. See whether it meets the SANS 10400 minimums before the plans go to council.

Room size and ventilation checkerFree tool · FloorPlan.co.za

01The room

02Windows that open the opening part only

Floor area
–
Volume
–
Opening window area
–
Opening area needed
–

    South Africa's national building regulations set minimum sizes for rooms in a home, minimum ceiling heights and how much window must open for fresh air. Plans that miss them are sent back by council, and rooms built too small can cause trouble when the house is sold. This checker tests one room at a time against the figures in SANS 10400-C (dimensions) and SANS 10400-O (lighting and ventilation), as summarised from the standard.

    The minimums it checks

    • Room size (SANS 10400-C): a habitable room, such as a bedroom, living room or study, needs at least 6 m² of floor, with no dimension under 2 m. Kitchens, sculleries, laundries and bathrooms are not held to this.
    • Ceiling height (SANS 10400-C): a bedroom needs 2.4 m over at least 6 m² of its floor; other habitable rooms in a home need 2.4 m over at least 70% of the floor and 2.1 m over the rest; bathrooms and toilets need 2.1 m wherever a person stands upright.
    • Natural ventilation (SANS 10400-O): the opening part of the windows should be at least 5% of the room's floor area, and not less than 0.2 m² in a small room. Where that is not possible, mechanical ventilation such as an extractor fan can be used.

    The figures come from published summaries of the standard; your draughtsperson works to the full, current edition and the deemed-to-satisfy rules in it, including daylight, which depends on where the windows are as well as their size.

    Minimum is not comfortable

    A 6 m² bedroom is legal, but it fits a single bed and little else. Most new homes use bedrooms of 9 to 12 m² and main bedrooms of 14 m² or more: see the house size calculator for typical sizes. Small homes, granny flats and backyard rental rooms are where the minimums really matter, because every square metre counts and rooms are often built close to the limit. A small house plan drawn by a registered draughtsperson gets the most out of the space while meeting the rules.

    Rooms in older houses and conversions

    Converting a garage into a bedroom, closing in a stoep or splitting a big room in two all change what the rooms must meet, and they need plans approved by council. A garage converted to a bedroom must meet the habitable room minimums, the ceiling height and the window rules. If the work was done without plans, the house will need As-Built Drawings for approval before it can be sold. See Extension Plans for alterations and additions.

    Frequently asked questions

    What is the minimum size of a bedroom in South Africa?
    Summaries of SANS 10400-C give 6 m² for a habitable room, with no dimension under 2 m, and a ceiling of 2.4 m over at least 6 m² of the floor. A comfortable bedroom is usually much bigger.
    What is the minimum ceiling height for a house?
    2.4 m for bedrooms and over most of other habitable rooms, with 2.1 m allowed over up to 30% of a habitable room's floor, and 2.1 m in bathrooms and toilets, according to summaries of SANS 10400-C.
    How big must the opening windows be?
    At least 5% of the floor area of the room for natural ventilation, and not less than 0.2 m², according to summaries of SANS 10400-O. A 12 m² bedroom needs 0.6 m² of window that opens.
    Can a room without a window be a bedroom?
    A bedroom needs natural light and ventilation under SANS 10400-O. A room with no window will usually not be approved as a bedroom. Ask a draughtsperson about skylights or other ways to light and ventilate it.

    Sources

    A guide for planning only. Your draughtsperson, architect or engineer and your municipality have the final word.

    Free quote request

    Request plan quotes

    Write the brief the way a draughtsperson would ask for it: the project, the rooms or the size, and where you are. Draughtspersons and architects who work in your area quote you directly.

    Client briefDwg PL-03 · scale 1:100

    01The project

    02The plan (optional, it sizes the job)

    BLOCK PLAN · NOT TO SCALE

    Floor area
    -
    Rooms
    -
    Storeys
    -
    Drawing fee
    -

    Choose the rooms to draw the plan. It is a sketch for the draughtsperson, not a design.

    Extras

    03Stand and timing

    04Drawing list (optional)

    1. L01
    2. L02
    Up to 12 lines: drawings, views or visits.
    Needs and options

    05Your details

    Free and no obligation. By sending you agree that we may share your request with suitable draughtspersons, architectural technologists or architects. See our privacy policy.